TR-8 Protection of Foundation Insulation

TR-8 Protection of Foundation Insulation

$500.00Price
1RCNY IA1
Insulation shall be visually inspected to verify proper protection where applied to the exterior of basement or cellar walls, crawl-space walls and/or the perimeter of slab-on-grade floors.

1RCNY IIA1
Insulation shall be visually inspected to verify proper protection where applied to the exterior of basement or cellar walls, crawl-space walls and/or the perimeter of slab-on-grade floors.
0/500
  • Details

    SIGN-ON / Inspect / SIGN-OFF (package)
  • Why Foundation Insulation Needs Protection

    Exterior foundation insulation is one of the most effective tools for reducing heat loss through a building's below-grade envelope, but the insulation itself is vulnerable to UV degradation, physical damage from backfill and landscaping, and moisture infiltration if left exposed. NYC's Energy Conservation Code requires that any insulation applied to the exterior of basement or cellar walls, crawl-space walls, or the perimeter of slab-on-grade floors must be physically protected — and that protection must be verified by visual inspection during the TR-8 progress inspection.

     

    What "proper protection" means in practice:

     

    Accepted protection methods in NYC construction include:

    • Cementitious stucco or parging applied over foam board above grade
    • Rigid cement board or cementboard panels for above-grade exposed sections
    • HDPE drainage board or dimple mat used in below-grade applications
    • Aluminum or galvanized metal flashing at the insulation termination point

     

    Common insulation types requiring protection include extruded polystyrene (XPS) and expanded polystyrene (EPS) rigid foam boards, both of which degrade rapidly when exposed to sunlight or physical impact without a protective covering.

     

    Class 1 vs. Class 2 application: Both 1RCNY §IA1 (Class 1 — 1- and 2-family homes) and §IIA1 (Class 2 — multifamily residential) require the same visual inspection. The requirement applies equally to new construction and to gut-renovated buildings where the foundation assembly has been altered.

     

    Ready to schedule your TR-8 foundation insulation inspection? Contact EZTR1 to confirm compliance before your next DOB inspection milestone.

EZTR1 is a division of AKS Architectural & Engineering Services, LLP and is a NYC registered special inspection company. 

  • c-facebook
  • c-twitter
  • c-googleplus

Need Help? E-Mail us info@eztr1.com

Call Us: (646)  396 - 1924 

<?php include_once("analyticstracking.php") ?>

<script>
  (function(i,s,o,g,r,a,m){i['GoogleAnalyticsObject']=r;i[r]=i[r]||function(){
  (i[r].q=i[r].q||[]).push(arguments)},i[r].l=1*new Date();a=s.createElement(o),
  m=s.getElementsByTagName(o)[0];a.async=1;a.src=g;m.parentNode.insertBefore(a,m)
  })(window,document,'script','https://www.google-analytics.com/analytics.js','ga');

  ga('create', 'UA-104672461-1', 'auto');
  ga('send', 'pageview');

</script>

  • w-facebook
  • w-twitter
  • w-googleplus
bottom of page